  "key": "grid.usa.national.location_based",
  "served_version": "2026.299",
  "current_version": "2026.299",
  "archived": false,
  "factor": {
    "key": "grid.usa.national.location_based",
    "name": "US national grid electricity — location-based (eGRID)",
    "section": "grid",
    "activity_type": "purchased_energy",
    "factor": {
      "value": 0.349667,
      "unit": "kg CO2e per kWh",
      "gas": "CO2e",
      "basis": "direct combustion at the generator (eGRID total output emission rate); generation basis — transmission and distribution losses EXCLUDED",
      "gwp_set": "AR4_100",
      "country_iso3": "usa"
    },
    "source": {
      "id": "EPA_EGRID_2023",
      "cell_ref": "'US23'!X3",
      "retrieved": "2026-05-20"
    },
    "scope": {
      "ghg_protocol": "scope2",
      "category": "purchased_electricity"
    },
    "components": {
      "co2": {
        "value": 0.348,
        "unit": "kg CO2e per kWh",
        "gas": "CO2",
        "gwp_set": null,
        "cell_ref": "'US23'!U3"
      },
      "ch4": {
        "value": 0.000646369,
        "unit": "kg CO2e per kWh",
        "gas": "CH4_fossil",
        "gwp_set": "AR4_100",
        "cell_ref": "'US23'!V3"
      },
      "n2o": {
        "value": 0.001081364,
        "unit": "kg CO2e per kWh",
        "gas": "N2O",
        "gwp_set": "AR4_100",
        "cell_ref": "'US23'!W3"
      }
    },
    "note": "eGRID2023 rev2 (data year 2023, published 2025). US-national total output emission rate, all generation (location-based). Per-gas components converted from source-published gas mass (lb/MWh) to kg CO2e/kWh using AR4 100-yr GWPs (CH4=25, N2O=298) per EPA convention; factor.value is the source-published CO2e total.",
    "updated": "2026-05-20",
    "quality": {
      "activity_basis": "energy",
      "pcaf_inputs": {
        "supplier_specific": false,
        "activity_basis": "energy",
        "scope_applicability": "scope2",
        "note": "Inputs for a PCAF data-quality determination. We do not publish a PCAF score: it depends on your activity data and asset class, and the Standard's asset-class tables disagree — an average factor supports Score 2 for mortgages but not for listed equity. Place these inputs on your own asset-class table."
      },
      "representativeness": {
        "geographical": "country_specific",
        "technological": "measured",
        "temporal_lag_years": 0
      },
      "derived_by": "greencalculus",
      "derivation_version": "1.0.0"
    }
  },
  "provenance": {
    "source_id": "EPA_EGRID_2023",
    "source_name": "US EPA eGRID 2023 rev2 (data year 2023, published 2025)",
    "publisher": "US Environmental Protection Agency (EPA)",
    "issuer": "US Environmental Protection Agency",
    "url": "https://www.epa.gov/egrid",
    "cell_ref": "'US23'!X3",
    "retrieved": "2026-05-20",
    "licence": "US Government public domain",
    "redistributable": true,
    "redistributable_basis": "open licence with attribution — redistributable",
    "update_cadence": "annual (January, ~2yr lag from data year)"
  },
  "note": "Current version. Append @<version> to this URL for a past version; the archive begins at 2026.111."
}