  "key": "fuels.usa.natural_gas.kwh_gcv",
  "served_version": "2026.306",
  "current_version": "2026.306",
  "archived": false,
  "factor": {
    "key": "fuels.usa.natural_gas.kwh_gcv",
    "name": "US Natural Gas — stationary combustion (per kWh, HHV)",
    "section": "fuels",
    "activity_type": "stationary_combustion",
    "factor": {
      "value": 0.181234197,
      "unit": "kg CO2e per kWh",
      "gas": "CO2e",
      "basis": "HHV",
      "gwp_set": "AR5_100",
      "derived_from": "fuels.usa.natural_gas.mmbtu",
      "conversion": "1 mmBtu = 293.0710701722222 kWh exactly (Btu_IT = 1055.05585262 J; 1 kWh = 3.6 MJ)",
      "country_iso3": "usa"
    },
    "source": {
      "id": "EPA_GHG_HUB_2025",
      "cell_ref": "EPA GHG Emission Factors Hub 2025, Table 1, Natural Gas: CO2 53.06 kg/mmBtu, CH4 1.0 g/mmBtu, N2O 0.1 g/mmBtu — RESTATED per kWh from the published per-mmBtu value by exact unit conversion (1 mmBtu = 293.0710701722222 kWh exactly (Btu_IT = 1055.05585262 J; 1 kWh = 3.6 MJ)). The publisher does NOT publish a per-kWh figure; this row is a unit restatement, not a second measurement.",
      "retrieved": "2026-08-14"
    },
    "scope": {
      "ghg_protocol": "scope1",
      "category": "stationary_combustion"
    },
    "components": {
      "co2": {
        "value": 0.181048235,
        "unit": "kg CO2e per kWh",
        "gas": "CO2",
        "gwp_set": null,
        "note": "EPA Table 1 CO2 factor (as printed)"
      },
      "ch4": {
        "value": 0.00009554,
        "unit": "kg CO2e per kWh",
        "gas": "CH4_fossil",
        "gwp_set": "AR5_100",
        "note": "1 g CH4 x AR5 GWP 28 / 1000"
      },
      "n2o": {
        "value": 0.000090422,
        "unit": "kg CO2e per kWh",
        "gas": "N2O",
        "gwp_set": "AR5_100",
        "note": "0.1 g N2O x AR5 GWP 265 / 1000"
      }
    },
    "alternates": {
      "ar6_100": 0.181233515
    },
    "updated": "2026-08-14",
    "quality": {
      "activity_basis": "energy",
      "pcaf_inputs": {
        "supplier_specific": false,
        "activity_basis": "energy",
        "scope_applicability": "scope1",
        "note": "Inputs for a PCAF data-quality determination. We do not publish a PCAF score: it depends on your activity data and asset class, and the Standard's asset-class tables disagree — an average factor supports Score 2 for mortgages but not for listed equity. Place these inputs on your own asset-class table."
      },
      "representativeness": {
        "geographical": "country_specific",
        "technological": "measured",
        "temporal_lag_years": 0
      },
      "derived_by": "greencalculus",
      "derivation_version": "1.0.0"
    }
  },
  "provenance": {
    "source_id": "EPA_GHG_HUB_2025",
    "source_name": "US EPA GHG Emission Factors Hub 2025 (Tables 1, 2, 7, 9, 10 — stationary + mobile combustion, steam & heat, waste, business travel & employee commuting)",
    "publisher": "US Environmental Protection Agency (EPA)",
    "issuer": "US Environmental Protection Agency, Center for Corporate Climate Leadership",
    "url": "https://www.epa.gov/climateleadership/ghg-emission-factors-hub",
    "cell_ref": "EPA GHG Emission Factors Hub 2025, Table 1, Natural Gas: CO2 53.06 kg/mmBtu, CH4 1.0 g/mmBtu, N2O 0.1 g/mmBtu — RESTATED per kWh from the published per-mmBtu value by exact unit conversion (1 mmBtu = 293.0710701722222 kWh exactly (Btu_IT = 1055.05585262 J; 1 kWh = 3.6 MJ)). The publisher does NOT publish a per-kWh figure; this row is a unit restatement, not a second measurement.",
    "retrieved": "2026-08-14",
    "licence": "US Government public domain",
    "redistributable": true,
    "redistributable_basis": "open licence with attribution — redistributable",
    "update_cadence": "annual (January)"
  },
  "note": "Current version. Append @<version> to this URL for a past version; the archive begins at 2026.111."
}